UK Gas Network Monitor

How Great Britain’s gas network is coping right now — official shortage warnings, the week-ahead demand against the level that triggers a warning, where today’s gas is coming from (Norway, the North Sea, LNG ships, storage), how full storage is, the wholesale price, and a year of history. From National Gas Transmission’s live data.

Network status

gas day Mon 19 Oct (05:00–05:00) · live flows 16:59 UK time
No gas shortage notices. National Gas hasn’t issued a Gas Balancing Notification or Gas Deficit Warning for today or tomorrow.
6%Gas stressno gas notices · storage 73% full · demand 40% of trigger
188.5Supply now (mcm/day)gas flowing onto the national network
211.7Demand now (mcm/day)demand is above supply — drawing on linepack
73%Storage fullmedium-range sites; Rough is empty
7.45pWholesale price (per kWh)+15% vs 30-day average · 18-month high

Days of gas in reserve

an estimate · stored gas ÷ daily demand
≈ 7.2 days of today’s demand held in storage
Storage sites only, at today’s demand (174 mcm)7.2 days
Including LNG waiting in import-terminal tanks12.1 days
Storage only, on a day like the coldest of the last year (408 mcm, 5 Jan 2026)3.1 days
Including LNG tanks, on that coldest day5.2 days
Gas held: storage sites 13,847 GWh · LNG tanks 9,304 GWh

This is the headline “how many days could stored gas alone cover?” figure. In reality Britain never runs on storage alone: Norwegian and North Sea pipelines and LNG ships keep flowing every day, and storage fills the gap on cold days or if a supply fails. Storage also can’t be emptied all at once — each site has a maximum withdrawal rate. Gas is converted at about 11 GWh per mcm. For comparison, Germany and France can store enough for several weeks to months of demand.

Next 7 days — demand vs the warning trigger

million cubic metres (mcm) per gas day
Mon 19 Oct 174 / 457 38%
Tue 20 Oct 182 / 457 40%
Wed 21 Oct 182 / 475 38%
Thu 22 Oct 188 / 475 40%
Fri 23 Oct 181 / 475 38%
Sat 24 Oct 172 / 475 36%
Sun 25 Oct 172 / 475 36%

Bars are National Gas’s demand forecast; the marker is the Margins Notice trigger — the demand level at which forecast supply would be stretched. A notice is only issued when demand gets close to it. In a cold snap demand can roughly double, so watch for bars creeping towards the marker.

Where the gas is coming from

Norway (Langeled pipeline)37%
North Sea pipelines (UK & Norway)49%
LNG (ships)4%
Continental Europe0%
Storage10%
Terminalmcm/day
Easington
East Yorkshire — Norway’s Langeled pipeline, plus Rough storage
74.7
St Fergus
Aberdeenshire — North Sea gas from UK and Norwegian fields
50.0
Teesside
Central North Sea fields (CATS pipeline)
20.8
Bacton (UK fields)
Norfolk — southern North Sea fields
14.5
Milford Haven
Pembrokeshire — LNG from ships (South Hook, Dragon)
6.6
Isle of Grain
Kent — LNG import terminal
2.8
Bacton (interconnectors)
Norfolk — pipelines to/from Belgium and the Netherlands
0
Barrow
Cumbria — Irish Sea fields
0
Theddlethorpe
Lincolnshire
0

Where it’s going

Homes & businesses116.9 mcm/day
gas taken by the local networks (heating, cooking, small firms)
Power stations66.9 mcm/day
gas-fired electricity generation
Large industry2.1 mcm/day
sites connected directly to the national network
Exports to Ireland24.6 mcm/day
Moffat interconnector (Republic of Ireland, Northern Ireland, Isle of Man)
Exports to the Continent0.0 mcm/day
Bacton pipelines to Belgium and the Netherlands
Into storage1.1 mcm/day
gas being injected into storage sites
325.5 mcm Linepack now — the gas held inside the pipes themselves. It acts as a short-term buffer: it falls when demand runs ahead of supply during the day and is refilled overnight. Forecast lowest point today: 323.6 mcm.

Gas storage

gas held at each site, gigawatt-hours (GWh)

Britain has little gas storage compared with its neighbours — roughly a week or two of winter demand. Rough, once the UK’s largest store, currently holds no gas, so most reserves sit in the smaller medium-range sites (salt caverns that can be filled and emptied quickly) plus LNG tanks at the import terminals. Storage normally fills through the summer and is drawn down over winter.

Where Britain’s gas came from — last 12 months

daily supply by source, mcm/day · hover for the day

Norway (Langeled) is the Norwegian pipeline into Easington. North Sea pipelines carry UK fields’ gas and more Norwegian gas (via the FLAGS, Vesterled and SAGE pipelines to St Fergus), so Norway’s real share is bigger than the blue band alone — the country breakdown below separates it. Storage rises in winter as reserves are drawn down.

Gas imports by country — monthly

GWh per month · official statistics, about 3 months behind

Share of imports, last 12 months

Norwegian gas by pipeline, last 12 months

Imports only — gas produced in UK waters isn’t included. LNG arrives by ship, so its source countries shift month to month with world prices. Latest month: July 2026 (provisional). Source: DESNZ Energy Trends table 4.3 (SEP_26 release), Open Government Licence v3.0.

The last 12 months

daily figures · hover for values

Gas demand (mcm/day)

Storage full (medium-range, %)

Wholesale price — System Average Price (p/kWh)

Linepack at the start of each gas day (mcm)

How to read this

Gas Balancing Notification (the warning formerly called a Gas Deficit Warning) means National Gas expects more gas to be used than is coming in. It asks suppliers to bring more gas onto the network and big users to cut back. If that isn’t enough, a Network Gas Supply Emergency can follow, where the largest industrial users are switched off first; homes are protected and are the last to be affected.

The Margins Notice trigger is the demand level at which supply would be stretched; notices are only issued when the forecast gets close to it. A gas day runs from 05:00 to 05:00. Gas is measured here in million cubic metres (mcm); one mcm is roughly 11 GWh of energy.

Source & updates

Live flows, notices, forecasts, storage and prices from National Gas Transmission’s data portal (its free public API). Live figures are refreshed every 15 minutes and the history every 6 hours. This is the Great Britain national transmission system; Northern Ireland has a separate network. The “gas stress” score is our own indicative estimate, not an official measure.

Related: the UK Electricity Grid, the Global Situation Monitor and the Power cost calculator.